PSA-02 – induction (magnetic) loop controller. Designed to determine whether the car in front of the barrier. The PSA-03 wire is connected to PSA-02 with a section of 1 sq. mm.
| Working voltage | АС 230/110 V ±10%, 50 Hz |
| Rated power | 4,5 W |
| Voltage of relay | AC 120 V/ 3 А |
| Working temperature | -20°C~+65°C |
| Working humidity | 10% ~ 90% |
| Working frequency | 20 кHz~170 кHz |
| Time | Infinite presence/ limited presence 5 minutes |
| Reaction time | 10 ms |
| Recommended inductance of the coil | 80-300 µH |
| Size | 78х40х108 mm |